Seven installation skills of LCD splicing screen

Jun 12, 2021

Eine Nachricht hinterlassen

The actual effect of the LCD splicing wall interface Z is inseparable from its own quality. Naturally, it is also very related to the installation and processing technology. Today, I will share with everyone the things to pay attention to during the entire installation process of the LCD splicing wall.


01. Choose the installation method according to the site and requirements


According to different application sites, different installation methods can be applied. At this stage, Z generally has four installation methods: floor-standing server cabinet type, wall-mounted support frame, in-line support and column support.


Floor-standing server cabinet-style convenient system software movement; wall-mounted support frame type must take into account the wall load; built-in type saves indoor space and is more beautiful and generous; column-type support frame is conducive to mid-to-late maintenance, but it is firm to the road surface And the requirements for support frames are higher.


02. The installation surface can be leveled and antistatic


No matter which installation method is selected, the selected installation surface must be leveled and capable of carrying weight, because all the system software of the LCD splicing wall is relatively large in terms of volume and net weight.


In addition, the mounting surface must be antistatic to prevent damage to the quality of the interface.


03. The installation of natural environment light source should be suitable


The light source around the installed natural environment should not be too strong. If it is too strong, the interface on the display screen may not be visible.


Light sources (such as windows) that are likely to enter the display screen should be blocked when necessary. In addition, the lighting effect of the machinery and equipment is preferably turned off to ensure the normal operation of the machinery and equipment. There is no need to install a light in front of the display screen, just install a downlight.


04. Measure and calculate the engineering quantity list in advance


According to the size and installation location of the display screens of all new projects, the length and specifications of various lines required by the police station are calculated, and the requirements for all engineering projects are calculated.


In addition, pay attention to distinguish the power plug and the power cord when routing the cables, and install them in different areas to prevent impact.


05. Pre-buried inspection and repair safety channel


In order to facilitate maintenance in the future, it is necessary to pre-bury the inspection and repair safety passages. Nowadays, most engineering projects adopt the post-maintenance method, that is, to carry out maintenance behind the display screen. Sufficient inspection and repair safety passages must be vacated on the reverse side of the display screen. The total width is about 70 cm to one meter, and the requirements for the indoor space of the project are relatively high.


06. Ensure good natural ventilation for machinery and equipment


In the safety passage for maintenance, air conditioners or vents must be installed to ensure that the natural ventilation of the machinery and equipment is good.


The LCD splicing screen should be avoided as far as possible at the vent (1 meter up and down is good), and the wind from the vent should not be directed at the shell immediately to prevent the display from being damaged by uneven heat and cold.


07. The design scheme of the structure edging strip is disassembled


In order to maintain the LCD splicing wall more convenient in the future, the frame edging strip must be a detachable edging strip. The inner edge of the outer structure is about 25mm gaps embedded on each side of the outside of the wall, and the capacity of the large and medium-sized wall should be appropriately increased according to the number of rows.


In addition, in order to enter the shell maintenance in the middle and later stages, the inspection safety channel is not less than 1.1m wide under normal circumstances. The detachable decorative strip should be pressed against the edge of the display screen by 3-5 mm. After the housing and the display are completely installed in time, the detachable decorative strip will finally be fixed.


The installation of the LCD splicing wall is not like a normal display system, just simply put it on and install it. The above is the matters that must be paid attention to in the whole process of installation of LCD splicing screen. Technical professional matters should be handed over to technical professionals, and friends and professionals are recommended to install.


Wenwei Fuli


Thank you to every reader who has always applied to everyone's service platform. With everyone's motivation, application and feedback, you can continue to publish real materials and technical articles that can help people in our field and promote the development of the industry. In addition, we all If readers have anything else they want to master or have all suggestions, I'm still chatting in private and I hope you will come.


As a gratitude feedback, I collected and selected a compilation of all weak-current installation materials that can be called Z cattle in history, for everyone to learn for free. The materials include intelligent system integrated wiring system scheme design, intelligent system intelligent engineering text documents plus Summary of report materials, completion data of weak current installation projects, industry specifications for various industries of weak current installation, 15 system software scheme designs, and a compilation of materials for the construction and deployment of weak current projects.


Anfrage senden